| Metering Tube | Machined cast acrylic |
| Internal Components | 316L SS |
| Fitting Material | Standard: PVC |
| Optional: 316L SS, brass | |
| Inlet/Outlet Fittings | FNPT, vertical |
| O-Ring | Standard: EPR |
| Optional: Buna N, Viton |
Performance
| Capacities | Water | 7 GPH to 20 GPM |
| Air | 2.6 SCFH to 60 SCFM | |
| Scale | 50mm, 65mm, 100mm, 127mm, 250mm direct reading |
|
| Accuracy | ± 6% of full scale flow, 50mm scale | |
| ± 5% of full scale flow, 65mm scale | ||
| ± 4% of full scale flow, 100mm scale | ||
| ± 3% of full scale flow, 127mm scale | ||
| ± 2% of full scale flow, 250mm scale | ||
| Turndown | 10:1 | |
| Repeatability | 3% | 50 mm scale |
| 2% | 75 mm scale | |
| 2% | 100 mm scale | |
| 2% | 127 mm scale | |
| 0.5% | 250 mm scale | |
| Maximum Temperature | Liquid | 130° F (54° C) |
| Gases | 100° F (38° C) | |
| Maximum Pressure | Water | 125 psig |
| Air | 100 psig | |
| Ambient Temperature | 33° F to 125° F (1° C to 52° C) | |
Options
| Certified Calibrations | Conform to ISA RP 16.6 | |
| Scales | Any volumetric unit | |
Floats
Options for rotameter float materials and designs extend flow ranges for different fluids within a given rotameter tube design.

CAUTION: Meters used in gas service are designed to operate at 14.7 psia. Meters used in pressure gas service must be shielded using 3/8” polycarbonate to protect personnel and equipment in the event of tube failure.