TE-7P-MD-DC

TE-7P-MD-DC 90V Magnetic Drive Pump

March Pump’s industrial TE-7P-MD-DC is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation, chemical transfer, and scrubber systems. It is capable of generating a maximum flow of 39 gallons per minute at 10 feet, and its maximum head is 34 Feet (14PSI).

Unit 60Hz 50Hz
System US Metric US Metric
Max Flow 39 GPM 147 LPM 39 GPM 147 LPM
Max Head 34 FT 10.3 M 34 FT 10.3 M
Power 0.75 HP 0.559 KW 0.75 HP 0.559 KW

Electrical/Air: 90V DC

Inlet: 1-1/2″FPT

Outlet: 1″MPT

Wet End: Polypropylene (Impeller, Front Housing, Rear Housing), Viton (O-Ring), Ceramic (Shaft, Thrust Washer), Ryton/Teflon/Carbon (Bushing)

Max Internal Pressure: 50 PSI / 3.4 bar

Max Liquid Temperature: 190 °F /87 °C

Note: Product image may be different than actual product received.

Options:

  • This pump can also be made with Kynar and 316SS.
  • O-Ring: Viton, Teflon Encapsulated Viton, or Ethylene Propylene
  • Front Thrust Washer: Ceramic or Hastelloy
  • Shaft: Ceramic, Hastelloy, or 316 Stainless Steel
  • Imp. Bushing: Carbon, Ceramic, Mica Teflon, or Ryton/Teflon/Carbon
  • Motor Bracket: Aluminium or Plastic
  • Stainless Steel Tag

Perfect for Applications Including

Applications for the TE-7P-MD-DC Magnetic Drive Pump include chemical recirculation, chemical transfer, bicarbonate systems, deionized water systems, refrigerators, scrubber systems, detergent mixers, computer cooling, carbon arc furnace cooling, ion exchange recovery, and aquariums.

Great for Chemicals Including

The TE-7P-MD-DC has pumped Acetic Acid, Citric Acid, Ethylene Glycol, Formaldehyde, Hydrochloric Acid (Muriatic), Nitric Acid, Phosphoric Acid, Potassium Chloride, Potassium Hydroxide, Sodium Hydroxide (Caustic Soda), Sodium Chloride, Sulfuric Acid, Fresh Water, Salt Water, DI Water, and many more chemicals.  The TE-7P-MD-DC may have been modified to handle these chemicals.  This pump may have to be modified to pump specific gravities, viscosities, or elevated temperatures different then ambient water.  Please contact March Pump to review your application before using the TE-7P-MD-DC.